What was found
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND A .075 INCH CRACK AT STATION 639 AND STRINGER 1L FRAME TIE CLIP. REPLACED CLIP PER EO 5393G227 9AD 93-08-04, SB 737-53-1085). (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND A .075 INCH CRACK AT STATION 639 AND STRINGER 1L FRAME TIE CLIP. REPLACED CLIP PER EO 5393G227 9AD 93-08-04, SB 737-53-1085). (M)