What was found
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1.50 INCH CRACK 727D BETWEEN STRINGERS 27 LT AND RT OF FRAME. INSTALLED DOUBLER, NEW SHEAR TIES AND FLOOR ANGLE SUPPORTS PER SRM 53-00-07 FIG 203. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1.50 INCH CRACK 727D BETWEEN STRINGERS 27 LT AND RT OF FRAME. INSTALLED DOUBLER, NEW SHEAR TIES AND FLOOR ANGLE SUPPORTS PER SRM 53-00-07 FIG 203. (X)