What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .12 5INCH CRACK STATION 480 BETWEEN 5-8 RIGHT AND 5-9 RIGHT BODY FRAME. INSTALLED DOUBLER PER SRM 53-00-07 FIG 202 AND BAC ADVISORY 737258. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .12 5INCH CRACK STATION 480 BETWEEN 5-8 RIGHT AND 5-9 RIGHT BODY FRAME. INSTALLED DOUBLER PER SRM 53-00-07 FIG 202 AND BAC ADVISORY 737258. (M)