What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK STATION 867 BETWEEN STRINGER 8 RT AND STRINGER 9 RT FRAME. INSTALLED DOUBLER PER SRM 53-00-07 FIG 202. BAC ADVISORY 737258. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK STATION 867 BETWEEN STRINGER 8 RT AND STRINGER 9 RT FRAME. INSTALLED DOUBLER PER SRM 53-00-07 FIG 202. BAC ADVISORY 737258. (M)