What was found
CLT - DURING DROP IN CHECK VISUAL AND EDDY CURRENT, FOUND A 40 INCH SQUARE HEAT DAMAGED AREA APU TORQUE BOX UPPER WEB BS 1088 - BS 1121 LBL 40 RBL 40 WEB CENTER. INSTALLED NEW FLOOR WEB SECTION PER SRM 53-80-13. (X)