What was found
PIT - DURING C-6 CHECK, FOUND CORROSION IN TWO AREAS, 1 FT BY 1 INCH AT STATION 1463 CANTED FRAME LOWER MEMBER, LEFT OF CENTER. BLENDED OUT CORROSION AND INSTALLED TWO STRAPS .80 THICK PER EA 50321. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING C-6 CHECK, FOUND CORROSION IN TWO AREAS, 1 FT BY 1 INCH AT STATION 1463 CANTED FRAME LOWER MEMBER, LEFT OF CENTER. BLENDED OUT CORROSION AND INSTALLED TWO STRAPS .80 THICK PER EA 50321. (M)