What was found
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A .5 INCH BY .5 INCH AREA OF CORROSION (120 INCHES) AT FLOORBEAM STATION 1640 RBL 60 TO LBL 60. INSTALLED NEW 'T' CAP PER TYPICAL REPAIR 53-15-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A .5 INCH BY .5 INCH AREA OF CORROSION (120 INCHES) AT FLOORBEAM STATION 1640 RBL 60 TO LBL 60. INSTALLED NEW 'T' CAP PER TYPICAL REPAIR 53-15-01. (M)