CLT - DURING A Q-1 CHECK VISUAL INSPECTION, FOUND A .5 INCH BY .5 INCH AREA OF CORROSION ON FLOORBEAM AT BS 344 LBL 09 UPPER CHORD. REMOVED DAMAGED AREA AND INSTALLED REPAIR PARTS AND ANGLES PER REPAIR DOCUMENT 53-10-51. (M)