What was found
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .5 INCH BY .5 INCH AREA OF CORROSION AROUND NUTPLATE HOLES STATION 312 LBL 12 TO RBL 12 FLOORBEAM UPPER CHORD. CORROSION TASK NR C53-107-02. SPLICED IN A NEW 'T' CAP SECTION PER SRM 53-10-51. (M)