As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION AROUND FLOORBOARD SCREW HOLES .5 INCH BY .5 INCH BY 25 INCH STATION 344 BETWEEN LBL 14 TO RBL 11 UPPER CHORD FLOORBEAM. CORROSION TASK NR C53-107-02. INSTALLED NEW 'T' CAP AND SPLICED ANGLES PER TR 53-10-03 AND EA 62264. (M)