What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A .5 INCH BY .5 INCH BY 10 INCH AREA OF CORROSION STATION 967 LBL 5 TO RBL 5 FLOORBEAM. CORROSION TASK NR C53-107-02. INSTALLED REPAIR ANGLES PER SRM 53-30-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A .5 INCH BY .5 INCH BY 10 INCH AREA OF CORROSION STATION 967 LBL 5 TO RBL 5 FLOORBEAM. CORROSION TASK NR C53-107-02. INSTALLED REPAIR ANGLES PER SRM 53-30-51. (M)