What was found
PIT - DURING Q-1 CHECK, FOUND CORRODED MATERIAL 29.125 INCH 740MM AT BL 1127L STATION 3870-4610 T-CAP CORRODED BEYOND LIMIT. REPLACED T-CAP PER SRM CHAPTER 51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK, FOUND CORRODED MATERIAL 29.125 INCH 740MM AT BL 1127L STATION 3870-4610 T-CAP CORRODED BEYOND LIMIT. REPLACED T-CAP PER SRM CHAPTER 51. (M)