What was found
CLT - DURIGN Q-5 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK STATION 727B STRINGER 8R TIE CLIP. INSTALLED MODIFIED PART PER EO 5393G227 AD 93-08-04 SB 737-53-1085 R1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURIGN Q-5 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK STATION 727B STRINGER 8R TIE CLIP. INSTALLED MODIFIED PART PER EO 5393G227 AD 93-08-04 SB 737-53-1085 R1. (M)