As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLT - DURIGN Q-2 CHECK VISUAL INSPECTION, FOUND A 52 INCH ACROSS FLOORBEAM EACH SCREW HOLE 1 INCH BY 2 INCH AREA OF CORROSION STATION 294.5, LBL 7 RBL 45 FLOORBEAM UPPER CHORD. CORROSION TASK NR C 53-107-02. BURNISHED FLOORBEAM EXCEPT AT STATION LBL 7, REPAIRED DOUBLER ANGLES PER EA 62682 AND SRM 51-70-12. (M)