What was found
PIT - DURING C-4 CHECK, FOUND .5 INCH CRACKS AT LONGERON 14L, STATION 1104 CANTED FRAME. REPLACED FRAME FROM 11L TO 22L FLOOR FACTORY SPLICE PER SRM 53-03 FIG 30. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING C-4 CHECK, FOUND .5 INCH CRACKS AT LONGERON 14L, STATION 1104 CANTED FRAME. REPLACED FRAME FROM 11L TO 22L FLOOR FACTORY SPLICE PER SRM 53-03 FIG 30. (M)