What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 1 INCH AREA OF CORROSION AROUND NUTPLATE STATION 328 LBL 36 RBL 66 FLOORBEAM UPPER SURFACE FORWARD ENTRY T-CAP. CORROSION TASK C53-107-02. REPLACED T-CAP PER SRM 53-10-51 PAGE 220. (M)