As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND STRINGER CORROSION 1 INCH, WEB 1 INCH BY 2 INCH CORROSION FORWARD CARGO BS 500A STRINGER 26R AND WEB BETWEEN STATION 500 AND 500A. CORROSION TASK NR C53-208-01. STRINGER SPLICE REPAIR INSTALLED PER EA 62887 AND SRM 53-00-03 FIG 201. (M)