What was found
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND .5 INCH BY .5 INCH BY 37 INCHES OF CORROSION ON TOP OF FLOORBEAM AT STATION 377 LBL 25 TO RBL 12. FABRICATED 'T' CAP REPAIR AND SPLICE ANGLES PER SRM 53-00-51 PAGE 209-213E. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND .5 INCH BY .5 INCH BY 37 INCHES OF CORROSION ON TOP OF FLOORBEAM AT STATION 377 LBL 25 TO RBL 12. FABRICATED 'T' CAP REPAIR AND SPLICE ANGLES PER SRM 53-00-51 PAGE 209-213E. (M)