What was found
PIT - DURING Q1 CHECK, FOUND 1 INCH CRACK AT FORWARD CARGO CEILING STATION NR 8305 BL '0' LINE FRAME. LOCALLY MANUFACTURED PART. REPLACED 15 INCH LONG SECTION WHICH HAD A 1 INCH CRACK IN IT PER SRM REF 53-21-10, 51-70-07, 51-30-01 AND 51-10-02. (M)