What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK BS 887, S 9R FRAME. INSTALLED FILLER AND DOUBLER PER SRM 53-00-07 FIG 202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK BS 887, S 9R FRAME. INSTALLED FILLER AND DOUBLER PER SRM 53-00-07 FIG 202. (M)