What was found
CLT - DURING A Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION ON SURFACE STATION 222 RT 27 INCH ABOVE FLOORLINE ANGLE. CORROSION TASK NR C53-101-01. REMOVED SURFACE CORROSION PER SRM 51-10-6. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING A Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION ON SURFACE STATION 222 RT 27 INCH ABOVE FLOORLINE ANGLE. CORROSION TASK NR C53-101-01. REMOVED SURFACE CORROSION PER SRM 51-10-6. (M)