What was found
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 3 INCH AREA OF CORROSION BS 1660-1681 RBL 10 SHEAR WEB/ANGLE. INSTALLED NEW WEB/CHORD PER SRM 53-60-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 3 INCH AREA OF CORROSION BS 1660-1681 RBL 10 SHEAR WEB/ANGLE. INSTALLED NEW WEB/CHORD PER SRM 53-60-51. (M)