What was found
PIT - DURING Q-1 CHECK, FOUND 20 INCH APPROXIMATELY BY 2 INCH CORROSION ON BEAM AT BL 221R STATION 5805-6305. REPAIRED WITH MODIFIED 1155009 BEAM PER SRM 51-70-06, 53-12-10, 51-22-01, 51-40-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK, FOUND 20 INCH APPROXIMATELY BY 2 INCH CORROSION ON BEAM AT BL 221R STATION 5805-6305. REPAIRED WITH MODIFIED 1155009 BEAM PER SRM 51-70-06, 53-12-10, 51-22-01, 51-40-01. (M)