What was found
PIT - DURING C-5 CHECK, FOUND .20 INCH CRACK, CRACK EXTENDED .5 INCH BEYOND STOP DRILL IN WEB ATTACHED TO SKIN AT AFT FUSE INTERIOR, AT STATION 1087 LONGERON 4R. INSTALLED DOUBLER, TITANIUM .050 SRM 53-01 FIG 2 PER EA NR 51136. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING C-5 CHECK, FOUND .20 INCH CRACK, CRACK EXTENDED .5 INCH BEYOND STOP DRILL IN WEB ATTACHED TO SKIN AT AFT FUSE INTERIOR, AT STATION 1087 LONGERON 4R. INSTALLED DOUBLER, TITANIUM .050 SRM 53-01 FIG 2 PER EA NR 51136. (M)