What was found
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND A 6 INCH BY 6 INCH AREA OF CORROSION AT STRINGER 27L BS 500D CARGO FLOOR LEVEL FRAME. CORROSION TASK NR C 53-208-01. FABRICATED REPAIR PER SRM 53-00-07. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND A 6 INCH BY 6 INCH AREA OF CORROSION AT STRINGER 27L BS 500D CARGO FLOOR LEVEL FRAME. CORROSION TASK NR C 53-208-01. FABRICATED REPAIR PER SRM 53-00-07. (M)