CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK IN TIE CLIP BS 727A STRINGER 2L. INSTALLED NEW TIE CLIP PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK IN TIE CLIP BS 727A STRINGER 2L. INSTALLED NEW TIE CLIP PER SRM 51-10-02. (M)