What was found
PIT - DURING UNSCHEDULED MAINTENANCE, FOUND 4 INCHES OF CORROSION WITH CRACK IN SPLICE .5 INCH LONG AT LONGERON 23R FORWARD OF STATION 229 PRODUCTION SPLICE AND SPLICE CRACKED OVER CORROSION. INSTALLED SPLICE REPAIR PER EA 51369. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING UNSCHEDULED MAINTENANCE, FOUND 4 INCHES OF CORROSION WITH CRACK IN SPLICE .5 INCH LONG AT LONGERON 23R FORWARD OF STATION 229 PRODUCTION SPLICE AND SPLICE CRACKED OVER CORROSION. INSTALLED SPLICE REPAIR PER EA 51369. (M)