As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PIT - DURING CORROSION TRACK VISIT FOUND .75 INCH BY .25 INCH CORROSION AND .75 INCH BY .25 INCH CORROSION. BOTH AREAS CORRODED AT CENTER CARGO BEAM AT STRINGER 72 BETWEEN FRAME 11257 AND 12791. REMOVED CORROSION AND INSTALLED STRAP AT STATIN 11541 PER EA NR 51316. (M)