What was found
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK STATION 948 STRINGER 27R SHEAR TIE. REMOVED AND REPLACED PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK STATION 948 STRINGER 27R SHEAR TIE. REMOVED AND REPLACED PER SRM 51-10-02. (M)