What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 8 INCH CORROSION AT STATION 312 LBL 12 FLOOR SUPPORT. REMOVED AND REPLACED SUPPORT PER SRM 51-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 8 INCH CORROSION AT STATION 312 LBL 12 FLOOR SUPPORT. REMOVED AND REPLACED SUPPORT PER SRM 51-10-2. (M)