What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 30 INCH AREA OF CORROSION STATION 344 FLOORBEAM. SPLICED IN 'T' CAP AND DOUBLER PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 30 INCH AREA OF CORROSION STATION 344 FLOORBEAM. SPLICED IN 'T' CAP AND DOUBLER PER SRM 53-10-51. (M)