What was found
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND CORROSION 6 INCH BY 1 INCH VERTICAL WEB STATION 1418 LBL 15 SKIN. CORROSION TASK NR C53-155-02. INSTALLED NEW WEB PER SRM 51-10-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND CORROSION 6 INCH BY 1 INCH VERTICAL WEB STATION 1418 LBL 15 SKIN. CORROSION TASK NR C53-155-02. INSTALLED NEW WEB PER SRM 51-10-00. (M)