What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK STATION 178 BULKHEAD VERTICAL STIFFENER INBOARD FLANGE LBL 5.5 WL 184. FABRICATED REPAIR ANGLE AND STRAP PER SRM 53-10-08 FIG 205. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK STATION 178 BULKHEAD VERTICAL STIFFENER INBOARD FLANGE LBL 5.5 WL 184. FABRICATED REPAIR ANGLE AND STRAP PER SRM 53-10-08 FIG 205. (M)