What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FUOND A 1 INCH CRACK AFT END ANTENNA MOUNT FUSELAGE SKIN BOTTOM CENTER STATION 727 BL 0 . FABRICATED FILLER AND DOUBLER REPAIR PER SRM 53-00-01 FIG 202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FUOND A 1 INCH CRACK AFT END ANTENNA MOUNT FUSELAGE SKIN BOTTOM CENTER STATION 727 BL 0 . FABRICATED FILLER AND DOUBLER REPAIR PER SRM 53-00-01 FIG 202. (M)