What was found
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND CORROSION INTERCOSTAL AT STATION 1270-1280 STRINGER 27R UPPER CHORD. CORROSION TASK NR'S C53-155-02, C53-156-02, AND C53-163-02. REMOVED CORRODED ANGLE AND REPLACED PER SRM 51-10-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND CORROSION INTERCOSTAL AT STATION 1270-1280 STRINGER 27R UPPER CHORD. CORROSION TASK NR'S C53-155-02, C53-156-02, AND C53-163-02. REMOVED CORRODED ANGLE AND REPLACED PER SRM 51-10-00. (M)