What was found
CLT - DURING C-2 CHECK VISUAL INSPECTION, FOUND CORROSION FUSELAGE FRAME STATION 1480 BETWEEN STRIGNER 26L AND STRINGER 27L. CORROSION TASK NR C53-163-02/C53-164-02. INSTALLED REPAIR DOUBLER PER SRM 53-00-07 FIG 201 AND EA 63977. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-2 CHECK VISUAL INSPECTION, FOUND CORROSION FUSELAGE FRAME STATION 1480 BETWEEN STRIGNER 26L AND STRINGER 27L. CORROSION TASK NR C53-163-02/C53-164-02. INSTALLED REPAIR DOUBLER PER SRM 53-00-07 FIG 201 AND EA 63977. (M)