What was found
CLT - DURING C-2 CHECK VISUAL INSPECTION, FOUND CORROSION FUSELAGE FRAME STATION 1460 BETWEEN STRINGER 26L AND STRINGER 27L, CORROSION TASK NR C53-155-02. INSTALLED REPAIR DOUBLER PER SRM 53-00-07 AND EA 63977. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-2 CHECK VISUAL INSPECTION, FOUND CORROSION FUSELAGE FRAME STATION 1460 BETWEEN STRINGER 26L AND STRINGER 27L, CORROSION TASK NR C53-155-02. INSTALLED REPAIR DOUBLER PER SRM 53-00-07 AND EA 63977. (M)