What was found
PIT - DURING Q-1 CHECK, FUOND 1.25 INCH CRACK IN INTERCOSTAL BETWEEN CABIN FLOORBEAMS NR 965-980, C/L OF A/C UPPER FLANGE. INSTALLED DOUBLER MANUFACTURED FROM 7075T6 .032 INCH PER SRM 53-01, FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK, FUOND 1.25 INCH CRACK IN INTERCOSTAL BETWEEN CABIN FLOORBEAMS NR 965-980, C/L OF A/C UPPER FLANGE. INSTALLED DOUBLER MANUFACTURED FROM 7075T6 .032 INCH PER SRM 53-01, FIG 2. (M)