What was found
PIT - DURING Q-1 CHECK, FOUND .5 INCH LENGTH BY .21875 INCH WIDE BY .019 INCH DEEP CHAFE IN FRAME NR 1059 LONGERON 15L. INSTALLED DOUBLER PER SRM 53-01, FIG 2 SHEET 4 AND EA 51616. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK, FOUND .5 INCH LENGTH BY .21875 INCH WIDE BY .019 INCH DEEP CHAFE IN FRAME NR 1059 LONGERON 15L. INSTALLED DOUBLER PER SRM 53-01, FIG 2 SHEET 4 AND EA 51616. (M)