What was found
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 2 INCH FLANGE AT INTERCOSTAL BL 0 STATION 344, CORROSION TASK NR C53-107-02. REMOVED FLANGE AND INSTALLED DOUBLER PER SRM 51-70-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 2 INCH FLANGE AT INTERCOSTAL BL 0 STATION 344, CORROSION TASK NR C53-107-02. REMOVED FLANGE AND INSTALLED DOUBLER PER SRM 51-70-11. (M)