What was found
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AND SHEARED RIVETS AT WL 195 INTERCOSTAL RBL 24, BS 178. FABRICATED REPAIR PER SRM 53-10-08. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AND SHEARED RIVETS AT WL 195 INTERCOSTAL RBL 24, BS 178. FABRICATED REPAIR PER SRM 53-10-08. (M)