What was found
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 4 INCH CRACK AT BS 807 OBL FRAME. INSTALLED REPAIR PLATE AND FILLERS PER SRM 53-00-07. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 4 INCH CRACK AT BS 807 OBL FRAME. INSTALLED REPAIR PLATE AND FILLERS PER SRM 53-00-07. (M)