What was found
CLT - DURING A Q-2 CHECK, VISUAL INSPECTION, FOUND SEVERAL 1 INCH AREAS OF CORROSION AT STATION 967 BETWEEN LBL 10 AND RBL 50 FLOORBEAM. SPLICED IN NEW 'T' CAP PER SRM 53-10-09 AND EA 64202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING A Q-2 CHECK, VISUAL INSPECTION, FOUND SEVERAL 1 INCH AREAS OF CORROSION AT STATION 967 BETWEEN LBL 10 AND RBL 50 FLOORBEAM. SPLICED IN NEW 'T' CAP PER SRM 53-10-09 AND EA 64202. (M)