What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM STATION 986.5. SPLICED IN NEW SECTION OF FLOORBEAM 'T' CAP PER TR 53-60-01 AND EA 64288. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM STATION 986.5. SPLICED IN NEW SECTION OF FLOORBEAM 'T' CAP PER TR 53-60-01 AND EA 64288. (M)