What was found
PIT - DURING Q-1 CHECK, FOUND FORWARD CARGO DOOR FRAME CORRODED (2 INCH BY 3 INCH AREA) ON DOOR FRAME BETWEEN STATION 370-427. SPLICED IN NEW SECTION OF DOOR FRAME PER SRM 53-05 FIG 44. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK, FOUND FORWARD CARGO DOOR FRAME CORRODED (2 INCH BY 3 INCH AREA) ON DOOR FRAME BETWEEN STATION 370-427. SPLICED IN NEW SECTION OF DOOR FRAME PER SRM 53-05 FIG 44. (M)