What was found
PIT - DURING Q-1 CHECK, FOUND .5 INCH BY 30 INCH CORROSION ON FLOOR SUPPORT AT STATION 160 TO 200 INBOARD OF MED. CORROSION LEVEL 1, CORROSION TASK NR C646-53303. DEFECTIVE PART REPLACED WTH IDENTICAL PART PER SRM 53-11-1 PAGE 53. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK, FOUND .5 INCH BY 30 INCH CORROSION ON FLOOR SUPPORT AT STATION 160 TO 200 INBOARD OF MED. CORROSION LEVEL 1, CORROSION TASK NR C646-53303. DEFECTIVE PART REPLACED WTH IDENTICAL PART PER SRM 53-11-1 PAGE 53. (M)