What was found
PIT - DURING Q-1 CHECK, FOUND .5 INCH BY 4 INCH CORROSION AT FLOOR SUPPORT AT STATION 160 CENTER LINE TO FORWARD SERVIEC DOOR. CORROSION LEVEL 1, CORROSION TASK NRC46-53303. CLEANED CORROSION, ALODINED, PRIMED, MFG FLOOR SUPPORT NR 36 AND INSTALLED SUPPORT. (M)