What was found
PIT - DURING Q-1 CHECK, FOUND 1 INCH BY 6 INCH CORROSION AT FLOOR SUPPORT AT STATION 200 INBOARD OF SERVICE DOOR. CORROSION LEVEL 1, CORROSION TASK NC C46-53303. FLOOR SUPPORT CUT FROM STOCK EXTRUSION 70 75-T6. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK, FOUND 1 INCH BY 6 INCH CORROSION AT FLOOR SUPPORT AT STATION 200 INBOARD OF SERVICE DOOR. CORROSION LEVEL 1, CORROSION TASK NC C46-53303. FLOOR SUPPORT CUT FROM STOCK EXTRUSION 70 75-T6. (M)