What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 4 INCH BY 2.5 INCH CORRODED AREA AT STRINGER 20L AND STATION 911 AFT CARGO. INSTALLED J ANGLE, U CHANNEL, SHIMS AND CLIP PER SRM 53-10-3 AND SRM 51-20-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 4 INCH BY 2.5 INCH CORRODED AREA AT STRINGER 20L AND STATION 911 AFT CARGO. INSTALLED J ANGLE, U CHANNEL, SHIMS AND CLIP PER SRM 53-10-3 AND SRM 51-20-1. (M)