What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 827 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED FILLER AND DOUBLER PER SRM 53-00-07, 53-30-07, 53-60-07 AND EA 64326. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 827 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED FILLER AND DOUBLER PER SRM 53-00-07, 53-30-07, 53-60-07 AND EA 64326. (M)